What does an electroencephalogram of the brain show?

EEG of the brain in children, what is it? This is a type of study of the functioning of the cerebral cortex, based on the recording and display of electrical impulses. Do not worry about how safe the study is if you decide to do an EEG for your child:

  • The biocurrents flowing through the electrodes are very small and do not harm the child’s body.
  • The research equipment is pre-grounded.
  • To reduce discomfort, the surface of the sensors is moistened with gel or saline solution. If the child has not washed his hair, the skin will need to be wiped to degrease it.

An EEG of the child’s brain is prescribed by a neuropathologist to diagnose and clarify vascular and organic diseases of the brain. The study is absolutely safe and can be performed on newborns, infants, and older children.

What is the essence of the EEG procedure?

An electroencephalogram records electrical signals from brain cells and allows us to identify epilepsy, trauma, neoplasms, inflammatory processes, and changes in blood vessels. Pathology is indicated by disturbances in the electrical activity of neurons, which are recorded using special sensors placed on the patient’s head.

Using an electroencephalogram, the doctor can:

  • analyze the performance of the brain;
  • identify foci of pathologies;
  • assess the nature and extent of damage;
  • confirm or clarify the diagnosis;
  • monitor the effectiveness of the treatment.


In what cases is EEG prescribed?

After a conversation with the patient and studying the medical history, the specialist decides to prescribe encephalography. Typically, indications for an EEG are frequent headaches, sleep problems, fainting, fatigue and chronic fatigue.

Deterioration in well-being may be a sign of disorders in the functioning of the brain. The above ailments often arise due to:

  • vegetative-vascular dystonia;
  • cardiac dysfunction;
  • pathologies of blood vessels of the neck and head;
  • inflammatory processes in meningitis and encephalitis;
  • endocrine disorders;
  • malignant or benign neoplasms.

For patients suffering from epilepsy who have undergone neurosurgical interventions and head injuries, EEG monitoring is mandatory.

Price

The cost of EEG video monitoring depends on the qualifications of doctors, the quality of equipment, the quality of service and the room in which the patient is located during the study, and the clinic’s experience in the field of neurophysiology. The clinic's specialization in neurology provides a great advantage for the patient who wants to receive an accurate and definitive diagnosis.

Medical has been operating since 1988 - it has vast experience and a scientific base, as well as the best specialists. Video-EEG monitoring is carried out on elite neurophysiological equipment “Grass Telefeaktor” in special rooms with all the necessary equipment in compliance with world standards of EEG video monitoring

The diagnostic price may include consultation with specialists with analysis of the electroencephalogram in complex cases - participation in deciphering the results of the medical consultation examination. The cost also depends on the time of the study - multi-day EEG video monitoring is more expensive.

The diagnostic price may include consultation with specialists with analysis of the electroencephalogram in complex cases - participation in deciphering the results of the medical consultation examination. The cost also depends on the time of the study - multi-day video-EEG monitoring is more expensive.

How to prepare for an electroencephalograph examination?

Monitoring the electrical activity of the brain does not require complex training. During the examination, it is important to simply follow the doctor's instructions and remain calm. Flashes of light and noise are part of the procedure.

Three days before the examination, it is recommended to stop taking tranquilizers, anticonvulsants and sedatives. 24 hours before the examination, do not drink tea, coffee, energy drinks, or eat chocolate. The day before monitoring, wash your hair. Have a snack an hour before the examination. Before starting, loosen your hair and remove metal jewelry.

Indications and contraindications

Currently, indications for performing an EEG in children are:

  • Repeated repeated fainting;
  • Convulsive states;
  • Consequences of TBI;
  • Encephalopathy;
  • Neoplasms of the brain;
  • Sleep disorders;
  • Retardation in neuropsychic (impaired mastery of various skills according to age, speech impairment, lag in intellectual development, disturbances in reactions, emotional sphere), physical development;
  • Violation of the child’s reaction to external stimuli;
  • Pathologies of the fetus, a number of pathologies of the newborn that arose perinatally;
  • Attention deficit hyperactivity disorder (ADHD).

According to current data, there are no absolute contraindications to the study. However, the use of the method is limited in the presence of damage to the scalp (bleeding wounds, fresh sutures), the patient is being treated with sedatives, or an overly excited state.

Footnotes

  1. Bird, Jordan J.; Manso, Louis J.; Ekart, Aniko; Faria, Diego R. (September 2018). A Study on Mental State Classification using EEG-based Brain-Machine Interface
    . Madeira Island, Portugal: 9th international Conference on Intelligent Systems 2021.
  2. Bird, Jordan J.; Manso, Louis J.; Ekart, Aniko; Faria, Diego R. (September 2018). A Study on Mental State Classification using EEG-based Brain-Machine Interface
    . Madeira Island, Portugal: 9th international Conference on Intelligent Systems 2021.
  3. VLADIMIRSKY, B.M USE OF EEG FOR OBJECTIVIZATION OF DIAGNOSIS OF ATTENTION DEFICIENCY SYNDROME IN CHILDHOOD / B.M VLADIMIRSKY, A.A KOZHIN, A.E TAMBIEV A.E. // VALEOLOGY. – 2021. – . – No. 4. – P. 31-38
  4. FEATURES OF SPATIAL ORGANIZATION OF EEG RHYTHMS IN PATIENTS WITH PARANOID SCHIZOPHRENIA / V.K. Bochkarev [et al.] // JOURNAL OF NEUROLOGY AND PSYCHIATRY IM. CC KORSAKOV. – 2021. – T. 117, No. 1. – P. 29-35
  5. ELECTROENCEPHALOGRAPHIC CHARACTERISTICS OF PSYCHOVEGETATIVE DISORDERS IN COMBAT VETERANS / V.A. GOLOKOV [etc.] // BULLETIN OF MODERN CLINICAL MEDICINE. – 2015. – T. 8, No. 6. – P. 14-17
  6. Kuznetsova, E.I. INDIVIDUAL COMPARATIVE ANALYSIS OF EEG OF CHILDREN WITH LYMPHOID TUMORS IN THE ASSESSMENT OF NEUROTOXICITY / E.I. Kuznetsova, N.L. Gorbachevskaya, A.E. Tambiev A.E. // ONCOPAEDIATRICS. – 2021. – . – No. 4. – P. 74-81
  7. ELECTROENCEPHALOGRAPHIC CHARACTERISTICS OF PSYCHOVEGETATIVE DISORDERS IN COMBAT VETERANS / V.A. GOLOKOV [etc.] // BULLETIN OF MODERN CLINICAL MEDICINE. – 2015. – T. 8, No. 6. – P. 14-17
  8. INFLUENCE OF PARENTS’ PARTICIPATION IN CHILDREN’S EARLY GENERAL EDUCATION ON THE DEVELOPMENT OF EEG/EMG SIGNS OF MUSICAL PERFORMING ABILITIES / O.M. Bazanova [and others] // SCIENTIFIC NOTES OF THE CRIMEA FEDERAL UNIVERSITY NAMED AFTER V.I. VERNADSKY. BIOLOGY. CHEMISTRY. – 2021. – T. 2, No. 1. – P. 3-13
  9. KAMINSKA, A Child EEG (and maturation) / A KAMINSKA, M EISERMANN, P PLOUIN // Handbook of Clinical Neurology. – 2021. – . – T. 160, No. 3
  10. Bird, Jordan J.; Manso, Louis J.; Ekart, Aniko; Faria, Diego R. (September 2018). A Study on Mental State Classification using EEG-based Brain-Machine Interface
    . Madeira Island, Portugal: 9th international Conference on Intelligent Systems 2021.
  11. Kuznetsova, E.I. INDIVIDUAL COMPARATIVE ANALYSIS OF EEG OF CHILDREN WITH LYMPHOID TUMORS IN THE ASSESSMENT OF NEUROTOXICITY / E.I. Kuznetsova, N.L. Gorbachevskaya, A.E. Tambiev A.E. // ONCOPAEDIATRICS. – 2021. – . – No. 4. – P. 74-81
  12. REACTIVITY OF EEG SENSORMOTOR BETA RHYTHM IN CHILDREN AGED FROM FOUR TO FOURTEEN YEARS OLD / D.V. Galkin [and others] // SCIENTIFIC NOTES OF THE CRIMEA FEDERAL UNIVERSITY NAMED AFTER V.I. VERNADSKY. BIOLOGY. CHEMISTRY. – 2021. – T. 2, No. 4. – P. 8-20
  13. Kilaru Kessler, SA Practical Guide to Treatment of Childhood Absence Epilepsy / S Kilaru Kessler, E McGinnis, P PLOUIN // Pediatric Drugs. – 2021. – . – No. 21. – P. 15-24

How is an EEG performed?

The examination takes place in several stages.

Preparatory stage

  • the patient enters the office, protected from light and sound;
  • an encephalograph “cap” consisting of special sensors is put on it;
  • The sensor wires are connected to a device that records the bioelectric impulses of the brain.

Diagnostic stage

  • the encephalograph transmits data to the monitor in the form of a graph;
  • the power of electric fields and its distribution in different parts of the brain are recorded;
  • Functional tests are carried out: the patient is asked to blink, look at flashes of light, breathe less often or deeper, listen to a sharp sound.

Final stage

  • the electrodes are removed from the patient;
  • print out the results.

How long does the electroencephalogram procedure take?

A regular encephalogram (routine EEG or diagnosis of a paroxysmal state) takes from 20 to 30 minutes.

During the examination, a number of tests are carried out:

  • rhythmic photostimulation;
  • hyperventilation;
  • load in the form of slow blinking.

If it is necessary to evaluate certain brain functions, the specialist adds additional tests, which he informs the patient about in advance. Such tests include:

  • clenching your fingers into a fist;
  • being in the dark;
  • sleep deprivation for a certain period;
  • night sleep monitoring.

Interpretation of survey results

Even a qualified specialist is not always able to accurately name the cause of the patient’s poor health and immediately make a diagnosis. The doctor may be alerted to focal changes on the EEG. In this case, magnetic resonance imaging will be required to exclude a tumor or cyst.

When you contact a medical doctor, you will be able to undergo all examinations as quickly as possible, without delaying your visit to specialists.

If you need to do an EEG of the brain and you want to do it using modern expert-class equipment and in the shortest possible time, call the phone number listed on the website or leave a request in the feedback form.

Medical staff will answer your questions and conduct all necessary examinations within one business day. Let's take care of your health together!

Electroencephalographic montages

➥ Main article: Installation of EEG leads

The basis of electroencephalography is the registration of the potential difference between two points. The recorded and graphically displayed potential difference between the two electrodes is called the electroencephalographic lead . It is believed that the activity recorded under one electrode reflects the functional state of a cortical area with an area of ​​10 x 10 to 15 x 15 mm. To record the bioelectrical activity of all parts of the convexital cortex, it is necessary to use a sufficient number of leads for this task. Switching EEG leads into a specific system constitutes installation . Based on the method of recording activity, montages can be divided into bipolar and monopolar (Fig. 1).


Rice. 1. Classification of EEG montages

In bipolar montages, the leads are switched in successive “chains” either along the sagittal line or across it. Accordingly, such installations are described as longitudinal and transverse (Fig. 1). The name of the leads in bipolar montages corresponds to a pair of switched electrodes: for example, Fp1-F3, F3-C3, C3-P3, P3-O1, etc.


Rice. 2. Bipolar EEG montages

a-longitudinal, b-transverse

One of the common longitudinal montages is a montage representing sequential switching of electrodes over each hemisphere into two fronto-occipital circuits: a circuit through the parasagittal leads and a circuit through the temporal leads (Fig. 2, a). The scheme of such an installation has a characteristic appearance, which made it possible to give the installation an appropriate name: “double banana” (English), “doppelte Wapape” (German). When switching electrodes along the frontal lines, a transverse bipolar montage is formed (Fig. 2, b).

Monopolar montages can be divided into two types depending on the method of obtaining an “indifferent”, i.e., “zero” lead. In the first case, the reference electrode is located at a point so far from the brain that its activity tends to zero. The second method is based on “averaging” the signal from all active electrodes. This signal becomes the “averaged electrode” against which activity over each lead is assessed.

In referential montages , the location of an indifferent electrode on the earlobe, as experience shows, is a completely justified method, given the relatively low power of the EEG signal. The reference electrode is placed on the ipsilateral earlobe: electrodes A1 and A2, respectively (Fig. 3). Very often, a lead from two ear electrodes connected to each other is used as a reference electrode (AA is a combined ear referent), which makes it possible to reduce the influence of interhemispheric asymmetry on the referent (do not forget that the ear electrode is not so far from the temporal lobe, and when location in the temporal lobe of a powerful pathological source, for example an epileptic focus, a false hemispheric or diffuse spread of activity can be obtained).


Rice. 3. Monopolar EEG montages

a - referential montage; b - installation with separated ear electrodes; c - installation relative to the vertex (Cz)

In some clinical cases, for example, with an epileptic focus in the temporal lobe, the ear referent ceases to be an “indifferent” inactive electrode. In such a situation, electrodes “remote” from the skull, for example on the acromion process of the scapula, can be used as a reference. However, placing a reference electrode on distant parts of the body encounters a number of difficulties, mainly due to interference from other electrically active organs: the heart and striated muscles. The location of the “remote” reference electrode on the chin, bridge of the nose, and cheekbone is extremely rare and is, perhaps, only of historical interest. However, in situations where placing the electrode on the earlobe is undesirable for some reason, such a location of the referent is possible.

The vertex electrode Cz can be used as a reference electrode. The paradox is that, despite the obvious active nature of this electrode, due to its topographical central location, it has a level of activity that can be conditionally considered to be a certain average total level. The use of the Cz electrode with an average activity level marked the beginning of another method: the mathematical formation of a virtual averaged electrode

In installations with an averaged electrode (Av), a “point” (“source”) is used as such an electrode, to which all active electrodes located on the scalp of the subject are connected in parallel through identical, fairly large resistances. Connecting a large number of electrodes in parallel “averages” the activity and provides a relatively low amplitude of the total signal of the averaged electrode. As follows from the technical rationale for this technique, the number of averaged electrodes must be large enough so that the activity of an individual electrode does not make such a large contribution that it will distort the average signal. In practice, installations with an averaged electrode are used with a total number of electrodes of at least 16.

The average electrode can be formed separately for each hemisphere: the average electrode of the right hemisphere (AvR) and the left hemisphere (AvL). Since each active electrode is included in the mathematical model of the averaged electrode, the active electrodes are switched with the averaged electrode of the ipsilateral hemisphere.

When averaging, mathematical transformation procedures, for example Laplacian or Lemos, can be additionally used to level out disturbances from individual electrodes. Such a reference is designated as an “averaged weighted electrode” (AvW).

In the most general case, a monopolar lead is designated as a lead relative to the reference electrode. For example, Ol-Ref, O2-Ref. However, the referent is usually indicated. As a result, the lead name looks more specific, for example O1-A1, or O1-AA, or Ol-Av, or 01-AvW.

A variety of montages during EEG serves to solve the inverse problem of EEG - localization of the source of pathological activity. This section, dedicated to the EEG research methodology, does not imply a discussion on which montage - monopolar or bipolar - is better and, therefore, in what montage to record the EEG. In the era of paper-based encephalographs, specialists adhered to the rule of recording the EEG in several mandatory montages. The switching of 6-8 such installations was already “hardwired” into the device. Computer encephalography allows the EEG recorded in any montage to be switched to any other montage. The software of the encephalographic complex includes a so-called montage library. It is quite extensive. In addition, there is always the opportunity to create your own montage or your own library. A necessary condition is a sufficient number of electrodes. When using an EEG helmet (EEG-cap), the optimal number of leads is recorded. When working with bridge or cup electrodes, you should strive to apply at least 19-21 electrodes so as not to rob yourself during subsequent analysis of the data obtained.

The graphical representation of the EEG pattern (EEG screen images) implies the order in which the leads are presented “from top to bottom.” The graphical representation depends on the tasks being solved. In a general assessment of neurodynamics, the hemispheric leads are alternately reflected from top to bottom. When identifying interhemispheric differences, homologous leads of the right and left hemispheres can be displayed in pairs. The lowest channel, as a rule, records the ECG in standard lead II.

The neuroscience community has not developed standard requirements for screen imagery. Equally often one can find the representation of screen images as a sequence of leads from the frontal to the occipital, and vice versa. The order of presentation of the leads of the left and right hemispheres, as well as the sequence of hemispheric leads, are, perhaps, determined by established traditions in the laboratory and reflect the individual style of perception of the specialist (“I see it this way”). Still, you shouldn’t impose your style on others. A novice specialist needs to choose a style, develop it and stick to it. The sequence of leads should be logical, expedient, and should not be pretentious.

Rating
( 2 ratings, average 5 out of 5 )
Did you like the article? Share with friends:
For any suggestions regarding the site: [email protected]
Для любых предложений по сайту: [email protected]